Compare the 12 displayed Solis US inverter pages

Open the exact source-derived page, preserve the complete US model and suffix, then confirm current electrical design, grid/listing package, battery/backup pairing, documents, availability and terms.

Solis-1P(3.6-5)K-4G-USSingle Phase PV Inverter

Solis-1P(3.6-5)K-4G-US

Proven and reliable, the Solis 3.6-5 kW single phase string inverter family has been deployed in the United States and Canada since 2011. It has dual MPPTs which can be utilized in complex design environments. The maximum input current per string is up to 14A, which is compatible with new high-power and bifacial PV modules, increasing power density and improving compatibility. Built-in transmitter options enable further system flexibility. This product line is also certified PVRSS and UL3741 com

3.6-5 kWmaximum input current per string is up to 14AUL3741
View Details
Solis-1P(6-10)K-4G-USSingle Phase PV Inverter

Solis-1P(6-10)K-4G-US

Proven and reliable, the Solis 6-10 kW single phase string inverter family has been deployed in the United States and Canada since 2011. It has up to 4 MPPTs which can be utilized in complex design environments and leads the industry in flexibility. The maximum input current per string is up to 14A, which is compatible with new high-power and bifacial PV modules, increasing power density and improving compatibility. Built-in transmitter options enable further system flexibility. This product lin

6-10 kWup to 4 MPPTsmaximum input current per string is up to 14A
View Details
S6-GC30K-LV-US / S5-GC60K-LV-USThree Phase PV Inverter

S6-GC30K-LV-US / S5-GC60K-LV-US

S6-GC30K-LV-US and S5-GC60K-LV-US string inverters are suitable for three-phase commercial rooftop PV projects with grid voltage of 240 or 208VAC. Both string inverters have high input currents, which enable support of larger PV modules without compatibility issues, better supporting power density and flexibility. Wider operating voltages support operation for longer periods throughout the day, resulting in better system yields. Commissioning, operations and management are simplified through sta

UL3741PVRSS
View Details
S6-GC(25-60)K-USThree Phase PV Inverter

S6-GC(25-60)K-US

S6-GC(25-60)K-US is the preferred PV string inverter for large commercial rooftop PV projects. The inverter features 3/4 independent MPPTs with very wide full-power operating ranges that can bring more yield. String current up to 20A, perfectly accommodates new high-power and bi-facial PV modules. Easy-to-use online O&M tools make O&M more intelligent and convenient. Optimized DC&AC interconnection will reduce the cost of system cables. Type 4X, CS Anti-Corrosion Level can be installed in the ha

String current up to 20A
View Details
S5-GC(75-125)K-USThree Phase PV Inverter

S5-GC(75-125)K-US

S5-GC(75-125)K-US string inverters are suitable for three-phase commercial rooftop or ground mount projects and work efficiently with 600V or 1000VDC arrays. Solis string inverters have high input currents, which enable support of larger PV modules without compatibility issues, better supporting power density and flexibility. Wider operating voltages support operation for longer periods throughout the day, resulting in better system yields. Commissioning, operations and management are simplified

UL3741PVRSS
View Details
Solis-(125-185)K-EHV-5G-US-PLUSUtility Scale PV Inverter

Solis-(125-185)K-EHV-5G-US-PLUS

Inverters are 125 kW and 185 kW three-phase PV string inverters are designed for commercial and utility‑scale applications. They support 600 VAC grid connections with a 1500 VDC maximum input voltage and include AFCI protection. Both models feature 9 MPPTs. High‑rated DC inputs support Y‑type DC connections with up to 30 A per input and a maximum string current of 15 A, enabling compatibility with bifacial modules. Additional features include anti‑PID functionality to enhance long‑term system pe

125 kW185 kW9 MPPTs
View Details
S6-GU250K-EHV-US-M12Utility Scale PV Inverter

S6-GU250K-EHV-US-M12

Solis' largest three-phase, 1500 V DC PV string inverter, the 250K, features 12 independent MPPTs, enabling great redundancy in larger systems. Redundancy through a distributed method supports overall system uptime. With our high current rated DC inputs, systems can realize full capacity as well of their PV modules. Our system supports ease of installation with MC4 connectors, while maintenance is streamlined with SolisCloud and advanced, remote monitoring. Our fuse-free design supports long-ter

View Details
Solis-4200-MV Skid SolutionUtility Scale PV Inverter

Solis-4200-MV Skid Solution

Solis' Skid Solution supports larger scale projects to simplify implementation and work seamlessly with our 1500 VDC PV string inverters (250-350kW). We reduce complexity by placing all supportive architecture for your large project on a single skid. This MW Station can serve up to 4.2MW sites with a 20-foot container delivery for easy transport, with additional options built in like an AC combiner for optimum flexibility.

250-350kW
View Details
S6-EH1P(3.8-11.4)K-H-USEnergy Storage Inverter

S6-EH1P(3.8-11.4)K-H-US

The S6 (Series 6) hybrid energy storage string inverter is the latest in hybrid inverter technology, versatile and flexible for the growing solar storage marketplace. This easily scalable hybrid inverter can be DC-coupled to a variety of batteries post-installation as well as can be paralleled to add capacity. The S6 hybrid is a grid-forming inverter that supports the latest high-powered PV modules with 16A DC inputs at each MPPT. This product line is also certified PVRSS and UL3741 compliant wh

UL3741PVRSS
View Details
S6-EH3P(30-60)K-NV-YD-H-USEnergy Storage Inverter

S6-EH3P(30-60)K-NV-YD-H-US

Introducing the Solis Commercial Hybrid Series. High voltage, three-phase energy storage for commercial applications. The inverter series, which boasts a maximum charge/discharge current of 70A+70A across two independently controlled battery ports, enabling optimum flexibility and scalability for commercial projects today and tomorrow. Whether for on or off-grid applications, the Commercial Hybrid series supports more flexible and scalable solar+storage with key features as well as an open ecosy

View Details
S6-EH3P(30-60)K-NV-YD-H-US(21A)Energy Storage Inverter

S6-EH3P(30-60)K-NV-YD-H-US(21A)

Introducing the Solis S6-EH3P(30-60)K-NV-YD-H-US(21A) Series – a high-voltage, three-phase energy storage inverter designed for commercial applications and compatible with 3Φ 208V/240V/480V grids. This inverter series delivers a maximum charge and discharge current of 84A + 84A (60K) across two independently controlled battery ports. It also features four integrated MPPTs with a string current capacity of up to 21A, ensuring superior power performance. Whether for on-grid or off-grid use, the S6

View Details
Displayed inverter routes

Separate residential, commercial, utility and hybrid architectures

The US catalogue spans multiple electrical roles. Start from the site architecture before comparing power or family names.

Single-phase PV inverters

Two Solis-1P 4G-US pages cover displayed 3.6–10 kW family ranges. Confirm exact AC voltage, string voltage/current, MPPTs, module compatibility, shutdown/protection, monitoring, grid listing and model revision.

Three-phase commercial inverters

Three S5/S6 GC pages cover displayed 25–125 kW commercial routes. Compare DC voltage/current, MPPT/string allocation, AC service, transformer interface, protection, export control and required US project documents.

Utility-scale inverter and skid routes

Displayed pages include 125/185 kW, 250 kW and a 4200 MV Skid Solution. Treat the skid as a system package with inverter/MV interfaces; request a one-line, BOM, collection design, studies, tests and site responsibility matrix.

Energy-storage inverters

Four S6 EH pages span residential and commercial, single-/split-/three-phase and low-/high-voltage battery routes. Confirm exact battery pairing, backup output, transfer, PV/AC coupling, BMS, firmware, protection and regional listing.

Inverter RFQ checks

Six checks before shortlisting a Solis US inverter

A reviewable RFQ ties the full model to the array, AC/grid system, battery/backup duty, site environment and current evidence package.

Operating role and project scale

State residential or C&I string, utility plant, hybrid/storage or MV skid use; identify grid export, zero-export, backup and plant-controller requirements without transferring functions across families.

PV and MPPT design

Provide module data, temperatures, string length/count, orientations and shading; verify cold Voc, hot Vmp, Isc/Imp, maximum DC voltage, MPPT window, input current and string allocation for the exact model.

AC, grid and destination

Provide phase, nominal voltage/frequency, service/transformer/MV arrangement, grounding, export limits, grid requirements and authority/listing evidence required for the full US model and firmware.

Battery and backup interface

For S6 EH routes, provide exact battery model, LV/HV window, usable energy, BMS protocol and firmware plus critical loads, continuous/peak output, transfer, neutral/grounding, generator or parallel scope.

Protection, monitoring and site

Confirm integrated/external DC/AC protection, shutdown or AFCI functions where required, meters/CTs, datalogger, plant controls, communications, ambient/altitude, enclosure and service clearances.

Documents and commercial release

Request the exact datasheet, manual, compatibility evidence, listing/certificate references, firmware/settings, warranty, accessories, labels and serial traceability; confirm stock, lead time and substitution in writing.

Regional and system boundaries

A Solis US family page is not a universal project approval

Suitability depends on the complete model, electrical design, firmware, documents and authority requirements for the actual destination and configuration.

US catalogue scope is regional

US suffixes, UL/NEC-related evidence and grid packages should not be presented as a global portfolio or approval. Confirm supply and authority acceptance for the exact project location.

Similar family codes are not interchangeable

Series, phase, AC voltage, DC current, MPPT, battery class, firmware, listing and revision can differ between similar names. Keep the full code on design, RFQ, approval and shipment records.

Battery support is not universal pairing

LV/HV or hybrid labels do not prove compatibility with every battery. Confirm exact models, voltage/current, BMS protocol, firmware, approved list, module count and accessories.

MV skid is not a single inverter SKU

A skid solution introduces MV equipment, collection, protection, auxiliaries, civil/logistics, grid studies and commissioning interfaces. Define the package and EPC boundary rather than comparing its headline power to an inverter.

Continue the inverter review

Connect the shortlist to PV design and battery compatibility

Use the commercial PV solution for string/MV context and the compatibility guide for hybrid inverter and battery interfaces.

Solis US inverter FAQ

Questions to close before fixing a Solis inverter model

These answers organize procurement; final PV/ESS design, grid acceptance, backup behavior and commissioning remain model- and project-specific.

Does the Solis US catalogue represent the complete global Solis range?

No. This site currently displays 19 products sourced from the Solis US English catalogue. Treat model suffixes, electrical ratings, listings and files as regional until current availability and destination acceptance are confirmed.

How should a Solis PV inverter be matched to a module array?

Use the exact module, site temperatures, string length/count, cold Voc, hot Vmp, Isc/Imp, MPPT allocation and input-current limits, then confirm AC service, grid requirements, protection and the complete model documentation.

Can any battery be used with a Solis S6 energy-storage inverter?

No. Confirm exact inverter and battery codes, voltage/current windows, BMS protocol, firmware, approved pairing list, module quantity, cables/accessories and commissioning evidence. A low- or high-voltage label alone is insufficient.

What should a Solis US inverter RFQ include?

Include destination, operating role, exact model or target power, module/string design, phase/voltage/grid requirements, battery/backup data where applicable, protection/monitoring, requested files/listings, quantity, schedule and substitution rules.

Solis US inverter procurement

Solis US PV and Energy Storage Inverters Across Four Application Routes

Compare 12 displayed pages from the Solis US English catalogue: two single-phase PV inverter families, three three-phase commercial families, three utility-scale routes and four energy-storage inverter pages. These include string inverters, hybrid platforms and an MV skid solution with different project boundaries. Preserve the complete US model and suffix, then confirm PV input and MPPT/current limits, AC system, grid/listing package, battery and backup interface where applicable, protection, communications, exact documents, firmware, destination authority requirements, current availability and commercial terms.

Prepare a Solis US inverter RFQ

Send the project role, module/string and AC/grid data, exact model, battery/backup scope if applicable, protection, documents, quantity and delivery target.

Build Solis Inverter RFQ
Chat with Us