S6-EH3P(30-60)K-NV-YD-H-US(21A)
InverterEnergy Storage Inverter

Solis US C&I high-voltage hybrid review

Solis S6-EH3P(30-60)K-NV-YD-H-US(21A) C&I Hybrid Family

This Solis US commercial hybrid family uses the 21A suffix to identify its high-current PV-input generation. The current official flyer table covers 30K03, 40K04, 50K04 and 60K04 members, with 150-850 V MPPT operation, three or four MPPT trackers, two 150-800 V battery ports and 30-60 kW 480 V three-phase output. PV sizing, battery current, grid voltage code, backup overload and parallel operation vary by exact member and configuration and must not be borrowed from the older non-21A product route.

Current flyer members: 30K03 / 40K04 / 50K04 / 60K04PV route: 3 or 4 MPPT / 21 A per string / up to 100 kW recommended arrayBattery route: 2 ports / 150-800 V / 80 A or 84 A per portAC and backup route: 30-60 kW / 277/480 V table / 1.6x rated for 2 seconds
Build Your RFQ

Current source identity: official Solis US S6-EH3P(30-60)K-NV-YD-H-US(21A) page and flyer. This page is intentionally separated from the older similarly named non-21A route, whose input-current wording and document set differ.

Current document status

The official page provides a current flyer, manual and a certificate with covered model patterns. Before quotation, confirm the exact K0X or 30K03/LV voltage code, ordering string, current manual/certificate coverage, approved battery and firmware, RSD receivers, meter/CT, generator and parallel controls, utility settings, one-line, commissioning and warranty package.

Current 21A-family evidence

Preserve the 21A suffix and member-specific voltage code

The official table is specific to a newer high-current family and should not be merged with older route data.

Four flyer members

The current table lists 30K03, 40K04, 50K04 and 60K04. Rated output, PV recommendation, tracker count, battery current and AC current differ by member.

21 A string-current generation

The table shows 42 A per MPPT input path, corresponding to two strings at up to 21 A each, with 65 A short-circuit allowance and three or four MPPT trackers.

Dual high-voltage battery ports

Two 150-800 V battery ports are shown, with 80 A per port for 30K03 and 84 A per port for higher members. This is not a universal battery-module approval.

Grid and backup table

The flyer table is 3/N/PE, 277/480 V and 60 Hz, with less-than-10 ms single-inverter switching and up to 1.6 times rated apparent power for two seconds.

US commercial hybrid RFQ inputs

Six checks before selecting the 30-60 kW 21A configuration

Suffix, voltage, PV, battery, controls and site acceptance must map to the same released model.

Full ordering model and grid

State 30K03/40K04/50K04/60K04 or other released K0X code, 208/240/480 V requirement, utility, jurisdiction, export rule and required certification coverage.

PV tracker schedule

Provide module and string Voc/Vmp/Isc/Imp, minimum temperature, strings per MPPT, orientation and DC/AC target; verify the 21 A string-current and 1000 V limits.

Battery and BMS system

Provide exact battery racks/modules, voltage window, usable kWh, current, port allocation, BMS/protocol/firmware, approved compatibility and listing/warranty evidence.

Backup, generator and weak-grid duty

Provide critical-load kW/kVA, motor starts, imbalance, transfer tolerance, autonomy, generator ratings/control, grid pass-through and required black-start or reserve behavior.

Parallel, metering and communications

Define inverter count, cabinet/control architecture, meter/CT, anti-reverse-flow, demand management, CAN/RS485, SolisCloud, LAN/Wi-Fi/Bluetooth and optional 4G.

Engineering and acceptance files

Request one-line, current manual, certificate/model schedule, RSD compatibility, battery list, protection/settings, commissioning plan, warranty, packing and substitution control.

Suffix, battery and backup boundaries

Do not transfer non-21A data, maximum PV or overload claims across configurations

The complete model code and released document revision control the technical and regulatory scope.

21A and non-21A routes are different evidence sets

The older page uses different input-current marketing and files. Do not merge its specifications, compatibility or certification status into this 21A record.

Grid voltage follows the suffix

The current flyer table shows 277/480 V. Broader 208/240/480 V family marketing requires the exact K0X or LV variant and matching AC table, certificate and ordering code.

Battery amp-hours are not compatibility

Marketing support for 100-314 Ah modules does not prove voltage, current, BMS protocol, firmware, rack topology, listing or warranty approval for a particular battery.

Backup and parallel claims are conditional

Two-second overload, less-than-10 ms switching and up-to-ten-unit marketing require topology, mode, controls, load basis, protection, firmware and commissioning evidence.

Continue the commercial hybrid review

Connect the 21A inverter family to the project topology

Use the C&I solution for system responsibilities and the compatibility guide for battery approval evidence.

Solis S6-EH3P 21A FAQ

Questions to close before releasing the commercial hybrid BOM

The exact suffix and topology should control every specification and document.

Can specifications from the non-21A Solis page be used here?

No. Treat the 21A route as a separate family generation and use only files that explicitly cover the quoted full model or documented model pattern.

Does the family support all 208, 240 and 480 V grids with one unit?

Do not assume that. The current flyer table is 277/480 V. Select the exact K0X or LV voltage code and require matching AC data and certificates.

Does 100-314 Ah mean any battery module is compatible?

No. Confirm rack voltage/current, BMS protocol, firmware, approved list, port topology, listing and warranty for the exact inverter-battery pair.

What should the 21A RFQ freeze?

Freeze full ordering code, PV/MPPT schedule, battery racks and ports, backup/generator loads, parallel/control topology, meter/CT, RSD, certificates, commissioning, warranty and BOM.

Prepare an exact S6-EH3P 21A project RFQ

Send the full model/voltage code, PV strings, battery racks and firmware, critical loads, generator/grid, parallel topology, listings, controls and quantity.

Start with the product, application or project information you have. We can help identify the remaining configuration, document or delivery questions before a final quotation.

Verify the Solis C&I Hybrid

Related products

Solis-1P(3.6-5)K-4G-USSingle Phase PV Inverter

Solis-1P(3.6-5)K-4G-US

Proven and reliable, the Solis 3.6-5 kW single phase string inverter family has been deployed in the United States and Canada since 2011. It has dual MPPTs which can be utilized in complex design environments. The maximum input current per string is up to 14A, which is compatible with new high-power and bifacial PV modules, increasing power density and improving compatibility. Built-in transmitter options enable further system flexibility. This product line is also certified PVRSS and UL3741 com

3.6-5 kWmaximum input current per string is up to 14AUL3741
View Details
Solis-1P(6-10)K-4G-USSingle Phase PV Inverter

Solis-1P(6-10)K-4G-US

Proven and reliable, the Solis 6-10 kW single phase string inverter family has been deployed in the United States and Canada since 2011. It has up to 4 MPPTs which can be utilized in complex design environments and leads the industry in flexibility. The maximum input current per string is up to 14A, which is compatible with new high-power and bifacial PV modules, increasing power density and improving compatibility. Built-in transmitter options enable further system flexibility. This product lin

6-10 kWup to 4 MPPTsmaximum input current per string is up to 14A
View Details
S6-GC30K-LV-US / S5-GC60K-LV-USThree Phase PV Inverter

S6-GC30K-LV-US / S5-GC60K-LV-US

S6-GC30K-LV-US and S5-GC60K-LV-US string inverters are suitable for three-phase commercial rooftop PV projects with grid voltage of 240 or 208VAC. Both string inverters have high input currents, which enable support of larger PV modules without compatibility issues, better supporting power density and flexibility. Wider operating voltages support operation for longer periods throughout the day, resulting in better system yields. Commissioning, operations and management are simplified through sta

UL3741PVRSS
View Details