SUN-7/7.5/8K-G02P1-EU-AM2
String InverterSingle Phase String Inverter7-8kW

SUN-7/7.5/8K-G02P1-EU-AM2

Single Phase | 7-8kW | 2 MPPT

Single Phase7-8kW2 MPPT
Send Inquiry

Overview

SUN-7/7.5/8K-G02P1-EU-AM2 Single Phase | 7-8kW | 2 MPPT

Product Highlights

Features

2 MPP trackers, Max. efficiency up to 97.7%
01

2 MPP trackers, Max. efficiency up to 97.7%

Zero export application, VSG application
02

Zero export application, VSG application

String intelligent monitoring (optional)
03

String intelligent monitoring (optional)

04

Wide output voltage range

05

Anti-PID function (Optional)

06

Low start-up voltage of 80V

Specifications

ModelSUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2
PV String Input Data
Max. PV Input Power (kW)10.511.312
Max. PV Input Voltage (V)550
Start-up Voltage (V)80
MPPT Voltage Range (V)70-500
Rated PV Input Voltage (V)360
Max. Operating PV Input Current (A)18+26
Max. Input Short Circuit Current (A)27+39
No. of MPP Trackers/No. of Strings MPP Tracker2/1+2
AC Output Side
Rated AC Output Active Power (kW)77.58
Max. AC Output Apparent Power (kVA)7.78.258.8
Rated AC Output Current (A)31.9/30.534.1/32.736.4/34.8
Max. AC Output Current (A)35/33.537.5/35.940/38.3
Rated output voltage220/230 0.85Un-1.1Un L/N/PE
Rated Output Grid Frequency/Range(Hz)50/45-55, 60/55-65
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi<3%
DC Injection Current<0.5%ln
Efficiency
Max.Efficiency97.7%
Euro Efficiency97.2%
MPPT Efficiency>99%
Equipment Protection
DC Reverse Polarity ProtectionYes
AC Output Overcurrent ProtectionYes
AC Output Overvoltage ProtectionYes
AC Output Short Circuit ProtectionYes
Thermal ProtectionYes
Insulation Impedance DetectionYes
DC Component MonitoringYes
Arc Fault Circuit Interrupter (AFCI)Optional
Anti-islanding ProtectionYes
Residual Current DetectionYes
DC SwitchYes
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
LCD/LED DisplayLCD1602
Communication InterfaceRS485/RS232/WiFi/LAN
General Data
Operating Temperature Range (°C)-25 to +60℃, >45℃ Derating
Permissible Ambient Humidity0-100%
Permissible Altitude (m)3000m
Noise (dB)≤35
Ingress Protection(IP) RatingIP 65
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm)330×310×208.5(Excluding Connectors and Brackets)
Weight (kg)12.1
Warranty5years
Type of CoolingNatural Cooling
Grid RegulationIEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2