MIN 7000-10000TL-X/X2
On-grid PV InverterResidential PV Inverter

Growatt residential and small-project string-inverter review

Growatt MIN 7000-10000TL-X and MIN 7000-10000TL-X2 Inverters

MIN 7000/8000/9000/10000TL-X and the corresponding four TL-X2 members The verified source tables show 600 V maximum, 60-550 V MPPT and three trackers; TL-X uses 13.5 A tracker inputs with a 27 A third route on 9/10 kW, while X2 lists 16 A per tracker On the AC side, 7-10 kW single phase at a 220 V nominal table, with maximum output current from 33.5 to 45.5 A 98.1% maximum Select one complete model, voltage route and destination document set before quotation; family maxima, optional protection and certificate lists do not apply automatically to every member.

Released members: MIN 7000/8000/9000/10000TL-X and the corresponding four TL-X2 membersPV route: 600 V maximum, 60-550 V MPPT and three trackers; TL-X uses 13.5 A tracker inputs with a 27 A third route on 9/10 kW, while X2 lists 16 A per trackerAC route: 7-10 kW single phase at a 220 V nominal table, with maximum output current from 33.5 to 45.5 AEnclosure and efficiency: IP66; 18.2 kg TL-X or 20 kg TL-X2; 98.1% maximum
Build Your RFQ

Current source identity: official Growatt May 2026 MIN 7000-10000TL-X and TL-X2 datasheet set. The X and X2 tables share four power labels but differ in start voltage, tracker-current allocation, AC surge row, weight and listed compliance set.

Current document status

Before quotation, obtain the exact full model and suffix, current datasheet and manual, destination certificate/model schedule, approved grid profile, PV string schedule, AC collection and protection design, AFCI/PID/SPD option status, connector and monitoring hardware, firmware, warranty, packing and written substitution rules.

Current family evidence

Preserve the member, DC-input and AC-voltage boundaries

The official tables define a family, not one interchangeable column.

Released model columns

MIN 7000/8000/9000/10000TL-X and the corresponding four TL-X2 members

PV and MPPT architecture

600 V maximum, 60-550 V MPPT and three trackers; TL-X uses 13.5 A tracker inputs with a 27 A third route on 9/10 kW, while X2 lists 16 A per tracker

AC interconnection route

7-10 kW single phase at a 220 V nominal table, with maximum output current from 33.5 to 45.5 A

Protection and physical record

Type II DC surge protection is listed; the X table also shows Type III AC surge protection and AFCI is optional. IP66; 18.2 kg TL-X or 20 kg TL-X2

residential and small-project inverter RFQ inputs

Six checks before fixing the inverter member and BOM

Array, AC collection, options and destination evidence must map to the same released model.

Full model and destination

State the complete model/suffix, quantity, country, utility, service voltage/frequency, export or PPC rule and required grid-code, safety and EMC evidence.

PV string and MPPT schedule

Provide module Voc/Vmp/Isc/Imp, temperature coefficients, strings per tracker and orientation; verify cold Voc, operating voltage, tracker current, short-circuit allowance and connector/cable ratings.

AC collection and grid

Define inverter AC voltage, conductor/busbar, breaker or switchgear, transformer where applicable, grounding, fault level, voltage drop, reactive-power duty and point-of-connection limit.

Protection and ordering options

Freeze DC switch, SPD, AFCI, anti-PID, night SVG or other options by exact ordering code. A source row marked optional or variant-specific is not standard equipment for every member.

Monitoring and plant control

Confirm RS485/USB, Wi-Fi/LAN/4G/RF/PLC hardware, logger or ShineMaster/SEM route, meter/PPC/export control, communications-loss behavior, firmware and account ownership.

Documents and commercial control

Request current datasheet/manual, certificate model list, SLD and settings, warranty, packing, serial traceability, accessories, lead time and written approval for any substitution.

Family, option and performance boundaries

Do not move family maxima or certificate coverage between columns

The exact member, voltage route, firmware, array and destination documents remain controlling.

Variant tables remain separate

The X and X2 tables share four power labels but differ in start voltage, tracker-current allocation, AC surge row, weight and listed compliance set.

Maximum efficiency is not yield

98.1% maximum This is a datasheet maximum, not an annual-energy or every-operating-point guarantee; model, loading, temperature, clipping, wiring and availability affect yield.

Optional protection needs an order code

Type II DC surge protection is listed; the X table also shows Type III AC surge protection and AFCI is optional. Confirm factory option, external devices, settings, applicable manual and destination design instead of relying on a family headline.

Certificates do not transfer automatically

A downloads list may span members, suffixes and countries. Require the ordered full model on the current certificate schedule and use the destination grid settings and commissioning record.

Continue the residential and small-project review

Connect the exact inverter to the project design and controlled BOM

Use the solution and BOM guides to coordinate electrical interfaces, documents and responsibility boundaries.

Growatt MIN 7000-10000TL-X and MIN 7000-10000TL-X2 Inverters FAQ

Questions to close before releasing the inverter order

One exact member and one matching evidence set should support the quotation.

Which model columns are covered by the verified source?

MIN 7000/8000/9000/10000TL-X and the corresponding four TL-X2 members

Can one PV string design be used across the whole family?

No. 600 V maximum, 60-550 V MPPT and three trackers; TL-X uses 13.5 A tracker inputs with a 27 A third route on 9/10 kW, while X2 lists 16 A per tracker Check the exact member's tracker/string allocation, voltage and current against the selected module and site temperature.

Are AFCI, PID and other protection functions standard on every member?

Do not assume that. Type II DC surge protection is listed; the X table also shows Type III AC surge protection and AFCI is optional. Confirm the complete ordering code, external protection design, manual and destination requirements.

What should the RFQ freeze?

Freeze full model/suffix, PV strings, AC voltage and collection, transformer/grid interface, protection/options, monitoring/PPC, certificate set, firmware, warranty, accessories and quantity.

Prepare an exact Growatt MIN 7000-10000TL-X and MIN 7000-10000TL-X2 Inverters RFQ

Send the full member and suffix, module/string schedule, AC and grid design, protection/options, monitoring/control, destination documents, accessories and quantity.

Start with the product, application or project information you have. We can help identify the remaining configuration, document or delivery questions before a final quotation.

Verify the Inverter Configuration
Chat with Us